Stratal CAD

Tables and balloons on part drawings

Help centre · Sheets, plotting and exchange

Change bill of materials tables, list holes in a hole table and place and arrange balloons on 2D drawings of parts and assemblies. For mechanical designers preparing manufacturing drawings.

Before you start

Steps: change a BOM table

  1. Run Drawing > Tables > BOMOPTIONS and select or click the BOM table.
  2. At "Option [Columns/Sort/Title/Height/Reset]", choose:
    • Columns: the column titles in the order you want, for example Item,Qty,Part,Description. A title the BOM does not have is reported.
    • Sort: a column to order rows by, for example Qty, or -Qty for largest first. Numbers sort by value.
    • Title: a title row above the table.
    • Height: the text height.
    • Reset: every column in item order again.
  3. Balloons keep their item numbers.

Steps: make a hole table

  1. Run HOLETABLE (Drawing > Tables).
  2. Pick a view of a part that sees the holes end-on.
  3. Give the datum: a point in the view, or Enter for the model's origin.
  4. Click the table's corner.

Each row has a tag (a letter per kind of hole, numbered top to bottom, left to right), X and Y from the datum, and the size as HOLECALLOUT writes it. Tags are placed beside the holes. The table follows the part when it changes; run VIEWUPDATE to move tags with their holes, tag new holes and name tags whose hole is gone. A view of an assembly lists its parts' holes where they stand; holes cut in the assembly itself are not listed.

Steps: balloons

  1. AUTOBALLOON puts a balloon on every item of the view's BOM table that the view shows and that has no balloon yet, set in a ring around the view.
  2. BALLOONALIGN sets the selected balloons in a row or column through a point, at "Align [Horizontal/Vertical]", in their order, where they were along it, or evenly spaced at a spacing you give.
  3. BALLOONSTACK stacks the selected balloons of one table under the topmost on its leader, a number in each touching circle. Select one stacked balloon and run it again to split the stack.

Tips and common mistakes

Troubleshooting

Message or symptom What it means and what to do
"That is not a BOM table." You picked another object. Click the BOM table itself.
"Not changed: …" The change was refused for the reason shown. Fix it and try again.

Related

Related

Still stuck? Open a support ticket or use Help, then Contact support in Stratal CAD.