Sign a drawing off, lock it against changes, record sign-offs by role, sign it digitally, and check later whether it changed. For checkers, engineers and quality staff.
Before you start
- A licence that allows editing.
- The tools are on the Drawing tab, Standard and inspection group, approval menu. They work in drawings, parts and assemblies.
Steps: approve and lock
- Run
APPROVE. - At "Approved by (name):", type the name.
- At "Lock the drawing against changes [Yes/No]", press Enter for Yes.
- ApprovedBy and ApprovedDate are filled in, and a checksum of the drawing as it is now is recorded.
- A locked drawing refuses every change (objects, layers, styles, blocks and the other properties) until you run
UNAPPROVE. Undo can still take back the approval itself.
Steps: record a sign-off by role
- Run
SIGNOFF. - Choose Checked, Engineering, Quality or Manufacturing, or type a role of your own.
- Give the name. The sign-off records who, when and what was signed.
Steps: sign digitally
- Run
SIGNDRAWING. - The first time, Stratal CAD makes your own signing key, kept for your Windows account only and protected by Windows.
- The signature and your public key are kept in the drawing. A locked drawing can still be signed.
Steps: check the status
Run APPROVALSTATUS. It says who approved the drawing and whether it changed since, and for each role whether the
drawing changed since that sign-off. For a signed drawing it says it was signed by your key's fingerprint on a date
and is unchanged since, or that it changed since it was signed.
Withdrawing an approval
UNAPPROVE withdraws the approval, removes the lock, the sign-offs and the signature.
Tips and common mistakes
- There are no certificates or company keys. Tell people your key's fingerprint so they know a signature is yours.
- Sign as checked… and Sign as approved… in File > Drawing properties… fill in the names and dates only. They do not lock the drawing.
Troubleshooting
| Message or symptom | What it means and what to do |
|---|---|
| "the drawing is approved and locked; UNAPPROVE it before changing it" | The drawing is locked. Run UNAPPROVE if the change is intended, then approve it again. |
| "The drawing is approved and locked already (APPROVALSTATUS)." | It is already approved. Check APPROVALSTATUS. |
Related
Related
- Plotting a drawing to PDF
- Printing and plotting a drawing
- Setting up a sheet set
- Publishing and printing a sheet set
- Importing and exporting DXF
- Importing and exporting IFC
Still stuck? Open a support ticket or use Help, then Contact support in Stratal CAD.