Design aids for UK homes, not approvals. Check a house as you draw it against the Building Regulations for England, with each finding's reference, measured and required values and a marker on the model; then check householder permitted development and lay out the planning sheets.
6 Rowan Close: Building Regulations and permitted development check (fictional)
A four-bedroom house drawn with Plans to 3D Rooms is checked against the Approved Documents for England: the first specification fails 17 of 142 checks, the design changes clear every one, and the householder scheme passes permitted development after two changes. Room-by-room heat loss, condensation screening, schedules and an indicative Home Energy Model run complete the job; design aid only, not building control approval.
Made on 12 November 2026 with Stratal CAD 0.1.8 and UK Building Regs and Planning 0.5.0; later versions have changes since.
The job and its names are fictional. Pictures are resized only, not retouched; the figures are the software's own output.
The model in 3D
The picture above is a render made in Stratal CAD: 6 Rowan Close after the changes, garden side (render) (see the render larger). The live model is the job's own glTF file (1.1 MB, 9,420 triangles),
fetched only when you press the button and drawn in your browser with simple shading, so its colours and lighting are plainer than the render.
Click or tap the model to take control (the page scrolls past it until you do), then drag to turn it, right-drag or Shift-drag to move it,
and use the wheel or a pinch to zoom; press Escape or click outside to let go.
The job in numbers
Building Regs checks run (England)
142
Failures before the design changes
17 fail, 1 to check, 1 not assessed
Failures after
0 (142 pass)
Permitted development rows after
17 pass (2 fail before)
External walls, area-weighted U
0.261 to 0.207 W/m2K
Roof, area-weighted U
0.206 to 0.101 W/m2K
Fabric heat loss against the notional dwelling
159.3 to 112.6 W/K (notional 115.7)
Glazing share (Part O)
15.8% to 14.9%
Design heat loss at -2 C (estimate)
9,343 W to 8,361 W
Rooms and openings scheduled
17 rooms, 45 doors and windows
Gross internal area (PLANAREAS)
214.92 m2
Escape route, Bedroom 1
12.82 m
Home Energy Model delivered energy (indicative only)
14,346 kWh a year
A1 sheets
6 compliance sheets + 7 planning pack sheets
3D model for the web
9,420 triangles, 1.10 MB
Pictures
(opens a larger view)Ground floor as first specified: numbered findings on the plan, the plugin's findings table and the Building Regs check panel (opens a larger view)Home Energy Model results in the panel (indicative only, not a SAP or HEM compliance result) (opens a larger view)First floor as first specified: loft stair, low window, narrow doors and escape window marked (opens a larger view)Site plan with the proposals and the permitted development check (opens a larger view)Room-by-room heat loss in the panel (opens a larger view)The house from the south-east (render) (opens a larger view)From above (render)
Home Energy Model engine run on the dwelling (indicative only, REGSHEM)
Room-by-room design heat loss (REGSHEAT)
Condensation screening of each build-up (REGSFABRIC Condensation)
Room and door/window schedules with the values the checks read (REGSSCHEDULE)
Changes since the last check
Numbered mark-up and findings table that plot (REGSMARKUP)
A value per object when tagging (Each)
Escape route length for houses; stair headroom and handrails on Plans to 3D Rooms stairs
Planning pack with existing and proposed drawings at the largest scale
Live checking with jump-to-finding
Parts B, E, F, K, L, M, O, Q, S and the space standard (England); Wales and Scotland rule sets
U-value calculator with Annex F corrections and ground floors
Householder permitted development check (Classes A to G)
Readable report by Part (HTML, PDF) and CSV
What it does
New in 0.7.0
Added on 21 November 2026, with Stratal CAD 0.2.5.
PLAN45 tests each tagged extension against a neighbour's window by the 45-degree rule, in plan and elevation; a design aid, not a planning decision.
PLANPARTYWALL tags neighbours' buildings and foundation depths and lists the Party Wall Act notices (sections 1 and 6) the work may need; a design aid, not party wall advice.
PLANCIL estimates the Community Infrastructure Levy from the new floor space, the council's rate and any exemption to claim; an estimate, not a liability notice.
Check as you draw
Live checks on models made with Plans to 3D Rooms or tagged outlines.
REGSCHECK: the whole model against the rule set in use, each finding with its Approved Document reference
REGSLIVE: the panel and markers follow every change, with no need to check again
REGSGOTO: select and show a finding's objects, or step to the next failure
REGSSTOREY: show one storey's markers, or every storey's
REGSMARKUP: numbered markers and a findings table on their own layers, so they plot with the drawing
What it checks
England's Approved Documents for dwellings.
Part K stairs and guarding; Part M doors, corridors and level access; Part B escape windows and inner rooms
The nationally described space standard
Part F ventilation; Part O overheating by the simplified method
Part E sound, Part Q security and Part S charge points
Wales and Scotland rule sets built in, or a rule set file of your own (REGSRULES)
Tell it what it cannot see
Values the drawing does not hold, on the objects.
REGSTAG: spaces, doors and windows with the values the checks need, parking spaces and dwellings
REGSSTAIR: a stair with its rise, going, width, headroom and handrails, or edit the selected one
REGSGUARD: guarding with its place and height; REGSROUTE: an escape route from the farthest point to the exit
REGSPROJECT: new dwelling, extension or change of use, and the overheating risk location
Part L fabric
U-values worked out from the layers.
REGSFABRIC: constructions with their layers, studs and ground floors, and their U-values
Area-weighted U-values of the thermal envelope against the limiting values
Fabric heat loss against the notional dwelling, and a fabric schedule
REGSFABRIC Condensation: each build-up screened for condensation
REGSHEAT: room-by-room design heat loss; REGSHEM: the Home Energy Model engine run on the dwelling, indicative only
Planning
Householder permitted development and the application sheets.
PLANSITE: the red line, the original house and its principal elevation
PLANPROPOSAL: extensions, roof additions, outbuildings, porches and hard surfaces
PLANPD: Classes A to G checked, each with the measured and allowed values
PLANAREAS: NIA, GIA and GEA; PLANLOCATION: checks the location plan you attach
PLANPACK: location and block plan, site plan, floor plans, elevations and the area schedule on sheets
Reports
Every finding with its attribution and the design-aid statement.
REGSREPORT: the findings as CSV, or a readable report by Part as a page or PDF
REGSSCHEDULE: room and door and window schedules with the values the checks read; the changes since the last check
Each finding says the rule, the item, what was measured and what is needed
Key commands
REGSCHECK
Check the model against the Building Regulations rule set in use
REGSLIVE
Turn live checking on or off: the panel and markers follow every change
REGSGOTO
Select and show a finding's objects (Enter: the next failure)
REGSTAG
Tag spaces, doors and windows with the values the checks need
REGSSTAIR
Draw a stair with its rise, going, width, headroom and handrails, or edit one
REGSGUARD
Draw or tag guarding with its place and height
REGSFABRIC
Constructions and their U-values, and the fabric schedule
REGSRULES
Choose England, Wales, Scotland or a rule set file, or show its source and edition
REGSREPORT
Write the findings as CSV, or a readable report by Part
REGSMARKUP
Markers at the failures and a findings table on their own layers
PLANSITE
Set the site: red line, original house, principal elevation and heights
PLANPROPOSAL
Tag footprints as extensions, roof additions or outbuildings
PLANPD
Check householder permitted development, Classes A to G
PLANAREAS
Area schedule (NIA, GIA, GEA) in the panel or as CSV
PLANPACK
Lay out the planning-application sheets
PLAN45
Test each tagged extension against a neighbour's window by the 45-degree rule, in plan and elevation (a design aid)
PLANPARTYWALL
Tag neighbours' buildings and foundation depths, then list the Party Wall Act notices (sections 1 and 6) the work needs
PLANCIL
Estimate the Community Infrastructure Levy from the new floor space, the council's rate and any exemption to claim
Specifications
Version
0.7.0 (the job above was made with 0.5.0 and Stratal CAD 0.1.8; later versions have changes since)
Rule sets
England (Approved Documents for dwellings) in full; Wales 22 rules (Parts K, M and B); Scotland 12 rules (stairs, barriers, escape windows, alarms); your own rule set files
Parts checked
K, M (M4(1)), B, F, L (fabric), O (simplified method), E, Q, S and the nationally described space standard
Planning
Householder permitted development, Classes A to G (England); area schedules; planning sheets PP-01 to PP-07
Output files
Findings as CSV, a report by Part as HTML or PDF, the fabric schedule and the area schedule as CSV
Works with
Plans to 3D Rooms 0.7.0 or later (optional): its rooms, walls, doors, windows, stairs and roofs are read directly
Requires
Stratal CAD 0.1.7 or later on Windows 11 (x64), with a licence that includes UK Building Regs and Planning
Delivery
A Stratal-signed plugin, installed from the Plugins menu; runs in Stratal CAD or isolated in its own process
Limitations
A design aid only: not building control approval, a planning decision, a Lawful Development Certificate or professional advice. You check the results.
The values in the rule sets were transcribed by Stratal and have not yet been checked by a building control or planning professional.
Part L is checked for the fabric only, with no thermal bridging; values are from the 2021 edition with its 2023 amendments. REGSHEM's Home Energy Model run is indicative only, not a SAP or HEM compliance result, and its space heating demand does not yet reconcile with the energy delivered to the boiler; some of its rows (lights and appliances, export) are wrong.
A first-floor room whose middle sits over a ground-floor partition can be counted as a heat-loss floor; finding numbers and opening names change after room edits, so a finding number can point to another item; the list of changes since the last check can show one finding as both resolved and new after a rename.
PLANSITE can take the wrong outline when the pick hits a shared edge, without saying which; PLANPD checks an infill extension beside an L-plan wing as a rear extension only; PLANAREAS does not flag a net internal area larger than the gross.
REGSMARKUP's rings at one point overlap, and with nothing to mark it leaves the previous mark-up on its layers. Tagging and fabric commands can be slow on a whole house (seconds to minutes each).
Wales and Scotland cover fewer Parts than England: no Welsh Parts F and L, and no Scottish space, accessibility, ventilation or energy standards.
Permitted development does not check Article 4 directions, planning conditions, materials, side-facing windows or the other Parts of the Order.
No maps are downloaded: you attach your own licensed location plan.
Spiral and helical stairs, loads on guarding and dynamic overheating modelling (TM59) are not checked.
The house in the pictures, 6 Rowan Close, its site, its proposals and the location plan are fictional. The model was made with Plans to 3D Rooms.
Add it to Stratal CAD