Stratal CAD

Object relationships and systems

Help centre · Drawing and editing

Connect objects port to port, put objects in containers, group them into systems such as a drainage network, and check the network for problems. For MEP, drainage and utility networks.

Before you start

Steps: connect two objects

  1. Type CONNECT.
  2. Pick the first object, then give its port (Enter takes its class's first port).
  3. Pick the second object and give its port.

A class can limit how many connections a port takes; a pipe end takes one.

Steps: build a system

  1. Type SYSTEM and give a name and a kind, for example drainage.foul.
  2. Choose Assign and select the objects to add. Unassign takes objects out.
  3. Erase removes the system; it is refused while objects are assigned to it.

Steps: check the network

  1. Type OBJGRAPH.
  2. It reports the connected groups of objects, required ports left free, problems, and each system's members.

Problems include connections to erased objects, ports a class does not define, ports with too many connections, assignments to missing systems and containment cycles.

Options

Command What it does
DISCONNECT Removes the connections between two picked objects.
CONTAIN Puts a picked object in a picked container (a site, a zone, a trench). A container inside its own contents is refused.

Example

Connect a manhole to a pipe: run CONNECT, pick the manhole and press Enter for its first port, then pick the pipe and press Enter. Run OBJGRAPH to see the group and any pipe ends still free.

Tips and common mistakes

Troubleshooting

Message or symptom What it means and what to do
Connecting is refused at a full port The port already has as many connections as its class allows. Use another port.
Connecting is refused for an unknown port The class has no port of that name. Press Enter for the first port.
Erase is refused for a system Unassign its objects first.

Related

Related

Still stuck? Open a support ticket or use Help, then Contact support in Stratal CAD.