Architecture, MEP, plant and coordination commands
Help centre · Drawing and editing
Walls, doors, windows, slabs and spaces; duct, pipe and tray runs; process piping; clash detection and coordination
issues. A command reference for building and plant designers; these tools are newer and still being refined.
Before you start
- A licence that includes 2D drafting.
- Walls and slabs get 3D bodies when the 3D geometry kernel is available.
- These commands are typed on the command line, or found with Edit > Find command… (Ctrl+F). Each is one undo
step.
Steps: a simple building
ARCHSTOREY: make a storey (name, elevation, height) and make it current.
ARCHWALL: draw walls along picked points or a polyline (width, height, justification, layer build-up). Junctions
with the storey's walls are cleaned.
ARCHDOOR and ARCHWINDOW: click a point on a wall. The wall's plan gets its gap, the door its swing and the
window its sill lines.
ARCHSLAB: make a slab from a closed polyline (thickness, level of its top).
ARCHSPACE: click inside walls, or pick a closed polyline, to make a room with its area and perimeter.
- After edits,
ARCHUPDATE rebuilds wall outlines, openings, space areas and 3D bodies.
For door, window and room schedules, use BIMSCHEDULE or SCHEDULE.
Commands: architecture
| Command |
What it does |
ARCHTYPE |
Makes wall, door and window types (named sizes and layers), applies one to picked objects, or lists them. |
ARCHUPDATE |
Rebuilds everything after giving typed objects their type's sizes. |
Commands: MEP
| Command |
What it does |
MEPRUN |
A duct, pipe or cable tray run by points or from a polyline: one segment per straight run, elbows at the bends, all connected and in a system. Branch starts it on another run with a tee; Riser draws a vertical run between two elevations. |
MEPCONNECT |
Joins a run end to equipment or a terminal, adding a reducer or transition where the sizes differ. |
MEPCHECK |
Finds open ends, size mismatches, flow-direction conflicts, missing systems and connected groups that mix systems, and selects them. |
MEPSIZE |
Checks flows against your own sizing table (CSV: Size, Max flow). |
Commands: plant
| Command |
What it does |
PLANTPIPE |
Routes a process line in 3D by points with elevations: pipes and elbows, connected and in a system named after the line number. Slope makes runs fall per metre. |
PLANTSPEC |
Checks every pipe, fitting and valve against your own pipe specs (CSV: Spec, NominalSize, Components). |
LINELIST |
Lists the process lines (size, spec, fluid, length, fittings, valves) to CSV and as a table. Takeoffs adds cut lengths from your take-off table. |
ISOMETRIC |
Draws an isometric of one line as 2D geometry: the route on 30 degree axes, lengths, fittings, valves and a cut list. |
PIDXCHECK |
Cross-checks the P&ID's line tags against the 3D pipes: present on both, same size and spec. |
Commands: coordination
| Command |
What it does |
BIMISSUE |
Coordination issues kept in the drawing: New at a point, List by status, Set a field, Zoom to one. (ISSUE is for issuing sheets.) |
CLASH |
Clash sets: hard clashes, and clearance clashes closer than a distance you give, between two sets of solids (by layer, class or all, federated models included) become issues. Update re-runs a set and resolves what no longer clashes. |
BCFEXPORT / BCFIMPORT |
Write issues to a BCF 3.0 file (.bcfzip); read BCF 3.0 or 2.1, matched by guid. |
FEDERATE |
Attaches other .stcad models read-only, lists them, checks their versions and reloads. Show copies a model's solids in to be seen, on a locked layer; Hide takes them out. |
OBJFIX |
Previews and applies the unambiguous fixes for the requirement rules' issues. |
IFCMAP |
Lists how object classes map to IFC entities. |
Example
Check services against structure: FEDERATE the structural model, then run CLASH with set A as the MEP layers and
set B as the federated model's solids. Each clash becomes an issue you can list with BIMISSUE and send to the
engineer with BCFEXPORT.
Tips and common mistakes
- IFC import and export need the IfcOpenShell component. IFC files are read in a separate restricted process.
- A second IFC import of the same building uses the drawing's own site, building and storeys.
Troubleshooting
| Message or symptom |
What it means and what to do |
| Walls have no 3D bodies |
The 3D geometry kernel is not available in this copy. The 2D plan still works. |
| A door or window is not placed |
Click on a wall of the current storey. |
| IFCEXPORT or IFCIMPORT says it is unavailable |
The IfcOpenShell component is missing. |
Related
Related
Still stuck? Open a support ticket or use Help, then Contact support in Stratal CAD.