Choose how lengths and angles are shown, which way angle 0 points and which way angles turn, and change the drawing's unit after it was made. For imperial, survey and international drawings.
Before you start
- A licence that includes 2D drafting.
- The drawing's unit (mm, m, in, ...) is chosen when you create the drawing. Use DWGUNITS to change it later.
Steps: set the display of lengths and angles
- Click View > Coordinates > Units… (
UNITS, aliasUN). The Drawing units dialog opens. - Under length, choose the Type (decimal, scientific, engineering, architectural, fractional) and Precision.
- Under angle, choose the Type (decimal degrees, degrees/minutes/seconds, grads, radians, surveyor's bearings), Precision, the Angle 0 direction and whether angles are measured clockwise. A sample shows the result.
- Click OK. It is one undo step, saved with the drawing.
-UNITS asks the same on the command line, starting with "Report formats [Scientific=1/Decimal=2/Engineering=3/
Architectural=4/Fractional=5]". Enter keeps each value.
Steps: change the drawing's unit
- Type
DWGUNITS. - At "Enter the drawing's unit [Unitless/Millimetres/Centimetres/MEtres/Inches/Feet]" choose the new unit.
- At "Scale the objects to keep their real size? [Yes/No] <Yes>":
- Yes makes a 1000 mm line a 1 m one. Text, dimension, multileader and table style sizes, linetype patterns, coordinate systems, named views, what layout viewports look at, constraint lengths, tables, balloons, drawing views, named cameras, point lights and multiline style offsets are scaled with the objects. References to blocks with insertion units only move, since their units convert them.
- No keeps the numbers: a 1000 mm line becomes a 1000 m one.
A change to or from Unitless always keeps the numbers. The whole change is one undo step.
How typed angles are read
- Polar coordinates (
@10<45) are measured from the angle 0 direction, in the angle direction. - A bearing (
@10<N45d30'E) names its own direction. - An angle typed without a unit is in the drawing's angle unit (grads or radians when that is the type, else
degrees).
d,r,g,'and"name their own unit. - Directions (a text's rotation, a dimension line's angle, XLINE Ang, the rotation of a block or image being placed) are measured from angle 0 in the angle direction. Turns (ROTATE, a grip rotation, UCS Z) turn clockwise when angles are measured clockwise.
- Other angles (an array's fill angle, chamfer and draft angles) are taken as typed.
Options
| Setting | What it affects |
|---|---|
| Length and angle precision | The status bar coordinates, dynamic input near the cursor and the UCS Manager. |
| Any setting that differs from the default | DIST, ID and LIST report in the drawing's format; DXF files carry the settings. |
Example
An architect's drawing in inches: open Units…, set length Type to Architectural with a precision of 1/16,
and angle Type to degrees/minutes/seconds. The status bar now shows 12'-6 3/16".
Tips and common mistakes
- Geometry is never rounded: only the display is.
- DWGUNITS with Yes is refused, with the reason, for a drawing with sketches or parametric solids, which follow their own dimensions.
Troubleshooting
| Message or symptom | What it means and what to do |
|---|---|
| "The drawing is already in ..." | You chose the unit the drawing already has. |
| "The drawing's unit stays ..." | You cancelled the scale question; nothing changed. |
| "Enter a whole number from ... to ..." | -UNITS needs one of the listed numbers. |
| Objects became 1000 times too big | You answered No. Undo, and run DWGUNITS again with Yes. |