Stratal CAD

Checking an assembly and exporting a parts list

Help centre · 3D, parts and assemblies

Check an assembly for clashes, write its bill of materials to CSV, update it when parts change, rename files safely and copy everything with Pack and go.

Before you start

Checking for interference

  1. Choose Assembly > Mates > Interference (INTERFERENCE, alias CLASH).
  2. At Clearance to report <0>: give a clearance, or press Enter.
  3. The command line lists components that overlap (with the overlap volume), components that touch, and pairs closer than the clearance.

Exporting a parts list

  1. Choose Assembly > Output > Export parts list… (BOMEXPORT, alias BOM).
  2. Choose the BOM type: Indented, TopLevel or PartsOnly.
  3. If the assembly has configurations, choose which one to list. The assembly does not switch.
  4. Choose where to save the CSV file.

Items are grouped by file, configuration and custom properties. Suppressed components and components excluded from the bill of materials are left out. Hidden components are listed.

Pack and go

  1. Save the assembly.
  2. Choose Assembly > Output > Pack and go… (PACKANDGO) and pick an empty or new folder.
  3. The saved assembly and every file it uses are copied there, the copies are rewritten to point at each other, and a manifest stratal-pack.json lists the size and SHA-256 checksum of each file.

Pack and go never overwrites files and stops if a reference is missing.

Renaming a file the assembly uses

  1. Choose Assembly > Assembly > Rename file (under the Insert component arrow, RENAMEFILE).
  2. Give the component, then the new file name (it stays in the same folder).
  3. At the next prompt, answer Folders to search other folders too (separate them with ;).
  4. The files that will change are listed and you are asked to confirm.

Everything is pointed at the new name: this assembly, and the assemblies and drawings in its folder and below (components, drawing views, BOM tables, derived solids). Documents open in other windows follow too (one undo step in each, not saved). An approved, locked drawing is left as it is and named. RENAMEFILE Undo undoes the last rename made from this assembly in this session, across the files.

Example

Check a gearbox for clashes with 0.5 mm clearance:

  1. INTERFERENCE, clearance 0.5.
  2. Fix the overlaps listed, then run it again until only expected contacts remain.

Tips and common mistakes

Troubleshooting

Message or symptom What it means and what to do
"Save the assembly first: pack and go copies the saved files." Save, then run Pack and go.
"Save the assembly first: it has changes that pack and go would not include." Save the changes first.
"Pack and go stopped: …" A referenced file is missing or the target folder is not empty.
"BOM not written: …" The file could not be written; check the folder and that the file is not open elsewhere.
"All referenced files are unchanged." ASSEMBLYUPDATE found nothing to read again.

Related

Related

Still stuck? Open a support ticket or use Help, then Contact support in Stratal CAD.